Offering you a complete choice of products which include boiler descaling chemicals, ph booster boiler chemical, boiler water chemical, ro ph booster chemical, boiler oxygen scavenger and boiler ph booster chemical.





₹ 95 / KilogramGet Latest Price
| Treatment Type | Descaling chemical |
| Application Area | Boiler |
| Application | Low pressure boiler, Thermic fluid heater, Waste heat boiler, High pressure boiler, CFBC boiler, Medium pressure boiler, AFBC boiler, Hot water boiler |
| Acid Type | Sulphamic |
| Pack Size | 50 KG BAG |
| pH | Acidic |
| Specific Gravity | 1.10 to 1.20 |
| Inhibitor Type | Corrosion Inhibited |
| Suitable Scale | Mixed Scale |
| Physical State | Powder |
Boiler descaling chemicals are specialized cleaning agents used to remove scale, rust, and mineral deposits from boiler heat transfer surfaces. Scale buildup occurs due to the precipitation of calcium, magnesium, and silica, which can reduce efficiency, increase fuel consumption, and cause overheating or failure of boiler components.
For most industrial and commercial systems, the procedure involves:
Isolation: The boiler is valved off from the main steam and water lines.
Pre-Flush: Rinsing with water to remove loose debris and sludge.
Chemical Circulation: The descaler is circulated (often using a dedicated pump) for 4–8 hours.
Neutralization: After the acid wash, a neutralizing agent (like soda ash) is circulated to restore a safe pH and prevent "flash rusting."
Final Rinse & Inspection: Flushing with clean water until the discharge is clear.




₹ 60 / KgGet Latest Price
| Minimum Order Quantity | 100 Kg |
| Booster Type | Alkaline |
| Physical State | Liquid |
| Chemical Type | pH Booster |
| Physical Form | Liquid |
| Application | Disinfection |
| Usage/Application | Industrial |
| Grade Standard | Technical Grade |
| Working pH Range | >12 |
| Compatibility | BOILER |
| Packaging Size | 50 kg |




₹ 85 / KilogramGet Latest Price
| Treatment Type | Antiscalant |
| Application | Low pressure boiler, Medium pressure boiler |
| pH | Alkaline |
| Specific Gravity | Below 1.10 |
| Packaging Size | 50 kg |
| Grade Standard | Bio-Tech Grade |
| Physical State | Liquid |
| Usage | Commercial, Industrial |
| Packaging Type | Drum |
| Usage Industry | Chemical plant, Food industry, Pharma plant, Sugar mill, Power plant |
Boiler water chemicals are specialized additives used to treat and condition boiler feedwater, ensuring efficient operation, preventing scale, corrosion, and sludge buildup. Proper chemical treatment enhances boiler performance, reduces maintenance costs, and extends equipment lifespan.




₹ 90 / KilogramGet Latest Price
| Minimum Order Quantity | 50 Kilogram |
| Booster Type | Blended |
| Application | Drinking Water |
| Physical Form | Liquid |
| Working pH Range | 6 to 8 |
| Packaging Size | 50 Kg |
| Physical State | Liquid |
| Usage | Commercial, Industrial |
| Packaging Type | Drum |
| Brand | Angel Chemical |
| pH Of Product | 10 to 12 |
RO (Reverse Osmosis) pH booster chemicals are additives used to adjust and maintain the pH level of water in RO systems. These chemicals prevent membrane damage, improve filtration efficiency, and enhance the quality of treated water.




₹ 75 / KilogramGet Latest Price
| Minimum Order Quantity | 50 Kilogram |
| Base Chemical | Sulfite based |
| Application | Feed water, Boiler water, Condensate line |
| Form | Liquid |
| Brand | Angel Chemical |
| pH | Neutral |
| Usage/Application | Water Treatment |
| Grade Standard | Technical Grade |
| Specific Gravity | Below 1.10 |
| Packaging Size | 50 Kg |
| Packaging Type | Can |
A boiler oxygen scavenger is a chemical additive used to remove dissolved oxygen from boiler feedwater, preventing corrosion and extending the lifespan of the boiler system. Oxygen in water can lead to pitting and rusting of metal surfaces, reducing efficiency and causing costly damage.




₹ 55 / KilogramGet Latest Price
| Minimum Order Quantity | 30 Kilogram |
| Booster Type | Alkaline |
| Application | Boiler Water |
| Physical Form | Liquid |
| Usage/Application | Industrial |
| Working pH Range | >10 |
| Compatibility | ALL METAL |
| Packaging Size | 50 kg |
| Physical State | Liquid |
| Usage | Commercial, Industrial |
| Grade Standard | Technical Grade, Reagent Grade |




₹ 95 / KgGet Latest Price
| Minimum Order Quantity | 50 Kg |
| Grade | Industrial Grade |
| Assay | 99% |
| Form | Powder |
| Application | Descaling |
| Usage/Application | Descaling Of Boiler And CT |
| Purity | 99.9% |
| Brand | Angel Chemical |
| Molecular Weight | 97.1 g/mol |
| Chemical Formula | H3NSO3 |
| CAS Number | 5329-14-6 |
Sulphamic Acid (H₃NSO₃) is a powerful acidic descaling agent widely used for removing mineral scale, rust, and deposits from industrial equipment, boilers, heat exchangers, and water systems. It is safe, non-volatile, and more user-friendly compared to hydrochloric acid.







₹ 80 / KgGet Latest Price
| Minimum Order Quantity | 500 Kg |
| Scale Type | Calcium scale |
| Application | Medium pressure boiler |
| Form | Liquid |
| Brand | Angel Chemical |
| Usage/Application | Industrial |
| pH | Neutral |
| Grade Standard | Technical Grade |
| Specific Gravity | 1.10 to 1.20 |
| Packaging Size | 50 kg |
| Packaging Type | Drum |
Antiscalant boiler chemicals are chemical additives used to prevent scale formation in boiler systems. Scaling occurs due to the precipitation of dissolved minerals, such as calcium, magnesium, and silica, which can reduce heat transfer efficiency, increase energy consumption, and damage boiler components.
Antiscalants don't usually remove minerals; they manage them using three main mechanisms:
Threshold Inhibition: The chemical interferes with the very early stages of crystal growth, keeping minerals soluble even when they exceed their saturation point.
Crystal Modification: If crystals do form, the antiscalant deforms them. Instead of neat, interlocking structures that stick to metal, they become "clunky" and blunt, making it harder for them to bond to surfaces.
Dispersion: It gives the mineral particles a negative charge, causing them to repel each other and the boiler walls. They remain suspended in the water as a fine "sludge" that can be easily removed via blowdown.



Nitin Patel (DIRECTOR)
Angel Chemicals Private Limited